Tandberg TR1A 50-60HZ
Start the console session.
Plug in serial cable to console port of device from PC COM1 port
Open PuTTY and select "Serial" connection type, leave baud rate (Speed) and other settings as default.
Plug power into device and if a power button exists, turn it on.
Erase Configuration
After the boot process completes type the reset_config command and confirm with y:
_cofx0 router id 1f
fx1 router id 1e
reset_config
Warning: This action is not reversible. Are you sure you want to continue? y
Configuration reset
154541.717 SYSTEM : Info : shutdown monitor - shutdown initiated
154541.717 C_LINK : Info : shutdown started
154541.717 MEDIA : Info : shutdown initiated
154541.813 MEDIA : Info : shutdown now complete
154541.857 NETCONF : Info : media connect on vfx0 (3)
154542.220 SYSTEM : Info : shutdown process - all priority 100 handlers complete
154542.220 SYSTEM : Info : shutdown process - shutdown complete
Waiting (max 60 seconds) for system process `vnlru' to stop...done
Waiting (max 60 seconds) for system process `fastpath' to stop...done
Waiting (max 60 seconds) for system process `bufdaemon' to stop...done
Waiting (max 60 seconds) for system process `syncer' to stop...
Syncing disks, vnodes remaining...0 0 done
All buffers synced.
Uptime: 32s
Rebooting...
cpu_reset: Stopping other CPUs
Host requested soft-reboot... Asserting nHOST_RESET
Copy all the output from the session into your records.
Right-click PuTTY's titlebar, from that dropdown menu click on "Copy All to Clipboard"
Open the file of record certifying the deconfiguration of this device and use CTRL V to paste all the output from PuTTY into that file. Formatting the text with a fixed-width font helps it look more readable.
End the session.
Close PuTTy.